Filtra
Visualizza 0-60 di 1194 risultati
Asta dal vivo
(Giorno 1 di 2)
Asta dal vivo
(Giorno 1 di 2)
Asta dal vivo
Asta a tempo
(Giorno 1 di 2)
Asta a tempo
(Giorno 1 di 2)
Asta a tempo
(Giorno 1 di 2)
Asta a tempo
(Giorno 1 di 2)
Asta a tempo
(Giorno 1 di 2)
Asta a tempo
(Giorno 1 di 2)
Asta dal vivo
Asta dal vivo
2007 Magnum 50 kW Generatore
Lloydminster, SK, CAN
Utilizzo: 12.045 hrs
2006 US EPA Label • John Deere 5030TF270C 4 Cylinder 80 hp 3.0 L Diesel Engine • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank
Asta dal vivo
Asta dal vivo
- Articolo 13406143
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 14.362 hrs
IronClad Assurance
- Articolo 13406136
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 12.115 hrs
IronClad Assurance
- Articolo 13406133
2018 (unverified) MAGNUM PRO MMG45IF4 Generator Set
North Franklin, CT
Utilizzo: 11.623 hrs
IronClad Assurance
- Articolo 13406135
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 12.276 hrs
IronClad Assurance
- Articolo 13406229
2017 (unverified) MULTIQUIP DCA25SSIU4F Generator Set
North Franklin, CT
Utilizzo: 10.052 hrs
IronClad Assurance
- Articolo 13406228
2014 (unverified) WACKER G 150 Generator Set
North Franklin, CT
Utilizzo: 16.902 hrs
IronClad Assurance
- Articolo 13406156
2019 (unverified) WACKER G25 T4F Generator Set
North Franklin, CT
Utilizzo: 13.751 hrs
IronClad Assurance
- Articolo 13406146
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 13.605 hrs
IronClad Assurance
- Articolo 13406150
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 18.585 hrs
IronClad Assurance
- Articolo 13406125
2017 (unverified) MAGNUM PRO MMG45IF4 Generator Set
North Franklin, CT
Utilizzo: 18.002 hrs
IronClad Assurance
- Articolo 13406173
2019 (unverified) MAGNUM PRO MMG45IF4 Generator Set
North Franklin, CT
Utilizzo: 16.240 hrs
IronClad Assurance
- Articolo 13406172
2019 (unverified) WACKER G25 T4F Generator Set
North Franklin, CT
Utilizzo: 14.179 hrs
IronClad Assurance
- Articolo 13155976
2019 Multiquip DCA45USI4CAN 45 kVA Mobile Generatore
Georgetown, ON, CAN
IronClad Assurance
- Articolo 13385986
2018 Prof Power Products MDG-23 Generatore
Conyers, GA
Utilizzo: 2369 hrs
IronClad Assurance
- Articolo 13348037
Diesel Engine • /10 kW Rated 3 Phase Output • 120 V / 208 V Rated Voltage • /10 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 120 V Receptacles
IronClad Assurance
- Articolo 13334763
2015 Multiquip DCA125USJMQRP 125 kVA Mobile Generator Set (Inoperable)
Yukon, OK
Utilizzo: 12.325 hrs
Tier 2 • 2015 US EPA Label • John Deere 6068TF275 6 Cylinder Diesel Engine • 125 kVA/ Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 120 V / 240 V Rated Voltage • Lunette Ring Carrier Trailer • Surge Brakes
- Articolo 13135856
Cummins K19 6 Cylinder Diesel Engine • 569 kVA/455 kW Rated 3 Phase Output • / 277 V / 480 V Rated Voltage • 120 V / 240 V Rated Voltage • Fuel Tank
- Articolo 10363619
2019 Multiquip DCA-25SSIU4F 20 kW Mobile Generator Set (Inoperable)
Glendale, AZ
Utilizzo: 9907 hrs
Tier 4 • 2019 US EPA Label • Isuzu BZ-4LE2T 4 Cylinder 30.0 kW 2.17 L Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 14.4 kVA •/14.4 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer
- Articolo 13230420
2016 Multiquip DCA-45SSIU4F 36 kW Mobile Generatore (Inoperable)
Stratford, CT
Utilizzo: 2798 hrs
Tier 4 • 2016 US EPA Label • Isuzu 4LE2X 4 Cylinder 2.17 L Diesel Engine • 45 kVA/36 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 26 kVA •/26 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Surge Brakes
- Articolo 13278647
2015 Multiquip DCA-25SSIU4F 20 kW Mobile Generator Set (Inoperable)
Afton, MN
Utilizzo: 4346 hrs
Tier 4 • Isuzu 4LE2T 4 Cylinder 2.17 L Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 14.4 kVA •/14.4 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer
- Lot 890
Kato 20SX9L 20 kW Mobile Generatore (Inoperable)
Lethbridge County, AB, CAN
Utilizzo: 9527 hrs
6 Cylinder Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 16.25 kVA •/13 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • Ball Hitch Carrier Trailer
Asta a tempo
- Articolo 13214670
2012 Multiquip DCA-70SSIU2 56 kW Mobile Generator Set (Inoperable)
Brighton, MI
Utilizzo: 13.325 hrs
US EPA Label • Isuzu BJ-4JJ1X 4 Cylinder 73 kW 2.99 L Diesel Engine • 70 kVA/56 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 40 kVA •/40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Surge Brakes
- Lot 8429
K4100D 4 Cylinder 30.1 kW Diesel Engine • /20 kW Rated 3 Phase Output • 208 V / 120 V Rated Voltage • 240 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank
Asta a tempo
(Giorno 3 di 3)
- Lot 8428
2013 Wacker Neuson G25 19.5 kW Mobile Generatore (Inoperable)
Lake Worth, TX
Utilizzo: 1182 hrs
2012 US EPA Label • Isuzu BV-4LE2 4 Cylinder 25.6 kW 2.2 L Diesel Engine • 24.4 kVA/19.5 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 16 kVA •/16 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Ball Hitch Carrier Trailer
Asta a tempo
(Giorno 3 di 3)
- Articolo 13214676
2015 Multiquip DCA-45SSIU4F 36 kW Mobile Generator Set (Inoperable)
Lemont, IL
Utilizzo: 8299 hrs
Tier 4 • 2014 US EPA Label • Isuzu BP-4LE2X 4 Cylinder 2.17 L Diesel Engine • 45 kVA/36 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 26 kVA •/26 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Surge Brakes
- Lot 6346
1995 Libby MEP-806A 60KW 60 kW Skid-Mounted Generatore (Inoperable)
Hebron, KY
Utilizzo: 2375 hrs
John Deere 6 Cylinder Diesel Engine • /60 kW Rated 3 Phase Output • 240 V / 416 V Rated Voltage • /50 kW • Rated Single Phase Output • 120 V / 208 V Rated Voltage • 120 V Receptacles • Sound Attenuated
Asta a tempo
(Giorno 2 di 2)
- Articolo 13290797
2010 Greenpower 100 kW Skid-Mounted Generator Set (Inoperable)
Batavia, OH
Utilizzo: 33.502 hrs
2010 US EPA Label • Iveco F4GE9685A 6 Cylinder 198 hp Diesel Engine • 125 kVA/100 kW Rated 3 Phase Output • 380 V / 440 V Rated Voltage • Bottom Mounted Fuel Tank • E-Stops
- Lot 7791
FSN MEP018A 10 kW Skid-Mounted Generatore (Inoperable)
Morris, IL
Utilizzo: 75 hrs
Hercules 4 Cylinder Gasoline Engine • /10 kW Rated 3 Phase Output • 120 V / 208 V / 240 V Rated Voltage • /10 kW • Rated Single Phase Output • 120 V / 240 V Rated Voltage • 120 V Receptacles
Asta a tempo
(Giorno 2 di 2)
- Lot 536
Stephill SE6000 Generatore (Inoperable)
Maltby, L3, GBR
Utilizzo: 3372 hrs
Yanmar 1 Cylinder Diesel Engine
Asta a tempo
(Giorno 2 di 2)
- Lot 6511
Cat 6 Cylinder Diesel Engine • Lunette Ring Carrier Trailer • Electric Brakes
Asta a tempo
(Giorno 2 di 2)
- Lot 6512
John Deere 6 Cylinder Engine • 280 kVA/224 kW Rated 3 Phase Output • Lunette Ring Carrier Trailer
Asta a tempo
(Giorno 2 di 2)
2014 Cummins C150D6R 150 kW Mobile Generatore (Inoperable)
Williston, ND
Utilizzo: 20.156 hrs
Cummins 6 Cylinder Diesel Engine • 187.5 kVA/150 kW Rated 3 Phase Output • 208 V / 240 V / 480 V Rated Voltage • 100.5 kVA •/100.5 kW • Rated Single Phase Output • 120 V / 277 V Rated Voltage • 230 V & 400 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Electric Brakes
Asta a tempo
(Giorno 1 di 2)
2018 General 40 kW Skid-Mounted Generatore (Inoperable)
Longmont, CO
Utilizzo: 10.522 hrs
2018 US EPA Label • Kubota V3800-DI-T-BG-ET01e 4 Cylinder 56.7 kW 3.8 L Diesel Engine • /40 kW Rated 3 Phase Output • 120 V / 208 V / 480 V Rated Voltage • 120 V / 240 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank
Asta a tempo
(Giorno 1 di 2)
961-1020 of 1194