Filtra
Visualizza 0-60 di 1146 risultati
Asta dal vivo
2007 Magnum 50 kW Generatore
Lloydminster, SK, CAN
Utilizzo: 12.045 hrs
2006 US EPA Label • John Deere 5030TF270C 4 Cylinder 80 hp 3.0 L Diesel Engine • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank
Asta dal vivo
- Articolo 13406135
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 12.276 hrs
IronClad Assurance
- Articolo 13406136
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 12.115 hrs
IronClad Assurance
- Articolo 13406172
2019 (unverified) WACKER G25 T4F Generator Set
North Franklin, CT
Utilizzo: 14.179 hrs
IronClad Assurance
- Articolo 13406229
2017 (unverified) MULTIQUIP DCA25SSIU4F Generator Set
North Franklin, CT
Utilizzo: 10.052 hrs
IronClad Assurance
- Articolo 13406143
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 14.362 hrs
IronClad Assurance
- Articolo 13406146
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 13.605 hrs
IronClad Assurance
- Articolo 13406150
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North Franklin, CT
Utilizzo: 18.585 hrs
IronClad Assurance
- Articolo 13406133
2018 (unverified) MAGNUM PRO MMG45IF4 Generator Set
North Franklin, CT
Utilizzo: 11.623 hrs
IronClad Assurance
- Articolo 13406228
2014 (unverified) WACKER G 150 Generator Set
North Franklin, CT
Utilizzo: 16.902 hrs
IronClad Assurance
- Articolo 13406125
2017 (unverified) MAGNUM PRO MMG45IF4 Generator Set
North Franklin, CT
Utilizzo: 18.002 hrs
IronClad Assurance
- Articolo 13406156
2019 (unverified) WACKER G25 T4F Generator Set
North Franklin, CT
Utilizzo: 13.751 hrs
IronClad Assurance
- Articolo 13406161
2019 (unverified) WACKER G50 T4F Generatore
Lake Point, UT
Utilizzo: 20.066 hrs
IronClad Assurance
- Articolo 13406149
2018 (unverified) MAGNUM PRO MMG45IF4 Generatore
Lake Point, UT
Utilizzo: 16.827 hrs
IronClad Assurance
- Articolo 13406177
2019 (unverified) MAGNUM PRO MLG15 Generator Set
Medford, MN
Utilizzo: 18.620 hrs
IronClad Assurance
- Articolo 13406120
2016 (unverified) WACKER G25 T4F Generator Set
North East, MD
Utilizzo: 18.106 hrs
IronClad Assurance
- Articolo 13406163
2019 (unverified) MULTIQUIP DCA15SPXU4F Generator Set
Medford, MN
Utilizzo: 18.938 hrs
IronClad Assurance
- Articolo 13406195
2021 (unverified) GENERAC MDG25IF4 Generatore
Lebanon, TN
Utilizzo: 15.338 hrs
IronClad Assurance
- Articolo 13406230
2019 (unverified) ALLMAND BR MP40 Generator Set
North East, MD
Utilizzo: 16.419 hrs
IronClad Assurance
- Articolo 13406127
2017 (unverified) WACKER G25 T4F Generator Set
North East, MD
Utilizzo: 12.888 hrs
IronClad Assurance
- Articolo 13406144
2018 (unverified) DOOSAN G25WDO-T4F Generator Set
North East, MD
Utilizzo: 20.257 hrs
IronClad Assurance
- Articolo 13406151
2018 (unverified) MAGNUM PRO MMG45IF4 Generator Set
Odessa, MO
Utilizzo: 17.793 hrs
IronClad Assurance
- Articolo 13406141
2018 (unverified) MAGNUM PRO MMG45IF4 Generator Set
Odessa, MO
Utilizzo: 17.270 hrs
IronClad Assurance
- Articolo 13406157
2019 (unverified) WACKER G25 T4F Generator Set
Medford, MN
Utilizzo: 16.577 hrs
IronClad Assurance
- Articolo 13406173
2019 (unverified) MAGNUM PRO MMG45IF4 Generator Set
North Franklin, CT
Utilizzo: 16.240 hrs
IronClad Assurance
- Articolo 13155976
2019 Multiquip DCA45USI4CAN 45 kVA Mobile Generatore
Georgetown, ON, CAN
IronClad Assurance
- Articolo 13385986
2018 Prof Power Products MDG-23 Generatore
Conyers, GA
Utilizzo: 2369 hrs
IronClad Assurance
- Lot 5662
Cat XQ500 455 kW Containerized Generatore (Inoperable)
Mont-Saint-Hilaire, QC, CAN
Utilizzo: 30.631 hrs
Cat 3456 6 Cylinder 691 hp Diesel Engine • /455 kW Rated 3 Phase Output • 600 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank
Asta a tempo
(Giorno 1 di 2)
- Lot 5869
2019 Wacker Neuson G50 38 kW Mobile Generatore (Inoperable)
Mont-Saint-Hilaire, QC, CAN
Utilizzo: 9506 hrs
2019 US EPA Label • Isuzu 4 Cylinder 49 kW 2.2 L Diesel Engine • 48 kVA/38 kW Rated 3 Phase Output • 600 V / 480 V / 240 V Rated Voltage • 32 kVA •/32 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Electric Brakes
Asta a tempo
(Giorno 1 di 2)
- Lot 5856
2010 Magnum 6 kW Mobile Generatore (Inoperable)
Mont-Saint-Hilaire, QC, CAN
Utilizzo: 1381 hrs
3 Cylinder Diesel Engine • 6 kVA •/6 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Ball Hitch Carrier Trailer
Asta a tempo
(Giorno 1 di 2)
- Lot 5877
Multiquip DAC-7000SSA 7.7 kW Skid-Mounted Generatore (Inoperable)
Mont-Saint-Hilaire, QC, CAN
Utilizzo: 3096 hrs
Tier 4 • 2010 US EPA Label • Kubota 2 Cylinder 9.2 hp .48 L Diesel Engine • 7.7 kVA •/7.7 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles
Asta a tempo
(Giorno 1 di 2)
- Lot 5866
54 kW Skid-Mounted Generatore (Inoperable)
Mont-Saint-Hilaire, QC, CAN
Utilizzo: 5248 hrs
2007 US EPA Label • Perkins 4 Cylinder 70.5 kW 4.4 L Diesel Engine • 68 kVA/54 kW Rated 3 Phase Output • 480 V Rated Voltage
Asta a tempo
(Giorno 1 di 2)
- Articolo 13425365
2019 MQ Power DCA70SSIU4FSG 56 kW Mobile Generatore (Inoperable)
Indianapolis, IN
2019 US EPA Label • Isuzu BR-4JJ1X 4 Cylinder 75 kW Diesel Engine • Requires Diesel Exhaust Fluid • 70 kVA/56 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 40 kVA •/40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Surge Brakes
- Articolo 13334763
2015 Multiquip DCA125USJMQRP 125 kVA Mobile Generator Set (Inoperable)
Yukon, OK
Utilizzo: 12.325 hrs
Tier 2 • 2015 US EPA Label • John Deere 6068TF275 6 Cylinder Diesel Engine • 125 kVA/ Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 120 V / 240 V Rated Voltage • Lunette Ring Carrier Trailer • Surge Brakes
- Articolo 13135856
Cummins K19 6 Cylinder Diesel Engine • 569 kVA/455 kW Rated 3 Phase Output • / 277 V / 480 V Rated Voltage • 120 V / 240 V Rated Voltage • Fuel Tank
- Articolo 10363619
2019 Multiquip DCA-25SSIU4F 20 kW Mobile Generator Set (Inoperable)
Glendale, AZ
Utilizzo: 9907 hrs
Tier 4 • 2019 US EPA Label • Isuzu BZ-4LE2T 4 Cylinder 30.0 kW 2.17 L Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 14.4 kVA •/14.4 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer
- Articolo 13391603
2016 Multiquip DCA-45SSIU4F 36 kW Mobile Generatore (Inoperable)
NOVI, MI
Utilizzo: 11.856 km
2016 US EPA Label • Isuzu BP-4LE2X 4 Cylinder 49 kW Diesel Engine • 45 kVA/36 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 26 kVA •/26 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer • Surge Brakes
- Articolo 13376363
2013 Multiquip DCA70SSIUMQRP 40 kW Mobile Generator Set (Inoperable)
Jarrell, TX
Utilizzo: 24.771 hrs
Tier 2 • US EPA Label • Isuzu FF-4GB1T 4 Cylinder 73.5 kW 4.3 L Diesel Engine • 70 kVA/40 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • /40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank • Surge Brakes
- Articolo 13278647
2015 Multiquip DCA-25SSIU4F 20 kW Mobile Generator Set (Inoperable)
Afton, MN
Utilizzo: 4346 hrs
Tier 4 • Isuzu 4LE2T 4 Cylinder 2.17 L Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 14.4 kVA •/14.4 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • Sound Attenuated • Bottom Mounted Fuel Tank • Lunette Ring Carrier Trailer
- Articolo 13497172
2017 Multiquip DCA-70SSIU4F 56 kW Mobile Generator Set (Inoperable)
El Paso, TX
Utilizzo: 9646 hrs
Tier 4 • 2016 US EPA Label • Isuzu BR-4JJ1X 4 Cylinder 2.99 L Diesel Engine • 70 kVA/56 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 40 kVA •/40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank • Ball Hitch Carrier Trailer • Surge Brakes
- Articolo 13473619
2018 Multiquip DCA-25SSIU4F 20 kW Mobile Generatore (Inoperable)
FORT MYERS, FL
Utilizzo: 8802 hrs
Tier 4 • 2018 US EPA Label • Isuzu 4LE2T 4 Cylinder 2.17 L Diesel Engine • 25 kVA/20 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 14.4 kVA •/14.4 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Ball Hitch Carrier Trailer
- Lot 8122
2021 US EPA Label • Cat C4.4 4 Cylinder 4.40 L Diesel Engine • 125 kVA/ Rated 3 Phase Output • 240 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank
Asta a tempo
- Lot 8124
2019 Multiquip DCA-70SSIU4F 56 kW Skid-Mounted Generatore (Inoperable)
Spokane, WA
Utilizzo: 11.690 hrs
Tier 4 • 2019 US EPA Label • Isuzu BR-4JJ1X 4 Cylinder 3.0 L Diesel Engine • 70 kVA/56 kW Rated 3 Phase Output • 240 V / 480 V Rated Voltage • 40 kVA •/40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank
Asta a tempo
- Lot 8123
2019 Multiquip DCA-70SSIU4F 56 kW Skid-Mounted Generatore (Inoperable)
Spokane, WA
Utilizzo: 10.042 hrs
Tier 4 • 2019 US EPA Label • Isuzu BR-4JJ1X 4 Cylinder 71 kW 3.0 L Diesel Engine • Requires Diesel Exhaust Fluid • 70 kVA/56 kW Rated 3 Phase Output • 480 V / 240 V Rated Voltage • 40 kVA •/40 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank
Asta a tempo
- Lot 6665
2018 Multiquip DCA-125SSIU4F 100 kW Skid-Mounted Generatore (Inoperable)
Chehalis, WA
Utilizzo: 16.088 hrs
Tier 4 • Isuzu BR-4HK1X 4 Cylinder 5.1 L Diesel Engine • Requires Diesel Exhaust Fluid • 125 kVA/100 kW Rated 3 Phase Output • 480 V / 240 V Rated Voltage • 72 kVA •/72 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles • Bottom Mounted Fuel Tank
Asta a tempo
- Lot 929
Mobile Generatore (Inoperable)
Moncton, NB, CAN
Lister petter 4 Cylinder Diesel Engine • Ball Hitch Carrier Trailer
Asta a tempo
- Lot 6664
Cat 3056 6 Cylinder Diesel Engine • 110 kVA/88 kW Rated 3 Phase Output • 408 V / 208 V Rated Voltage • 88 kVA •/88 kW • Rated Single Phase Output • 240 V Rated Voltage • 240 V & 120 V Receptacles • Sound Attenuated • Bottom Mounted Fuel Tank
Asta a tempo
- Lot 9097
Lema 100 kW Generatore (Inoperable)
Wasilla, AK
Utilizzo: 2760 hrs
Volvo 6 Cylinder Engine • 169 kVA/135 kW Rated 3 Phase Output • 277 V / 480 V Rated Voltage
Asta a tempo
- Lot 6666
1996 Multiquip DCA-25 SSI2 14 kW Skid-Mounted Generatore (Inoperable)
Chehalis, WA
Utilizzo: 3521 hrs
4 Cylinder Diesel Engine • 25 kVA/14 kW Rated 3 Phase Output • 480 V / 240 V / 120 V Rated Voltage • 14 kVA •/14 kW • Rated Single Phase Output • 240 V / 120 V Rated Voltage • 240 V & 120 V Receptacles
Asta a tempo
961-1020 of 1146